Window Installation Masonry / Concrete
Frame anchor
Window Production Plastics EJOT frame anchor type MA-D
®
Ø Length PU Order description Article number
Window Production Timber Zinc plated, blue passivated 100 Frame anchor MA-D 7.5x40 2 247 040 601
[mm]
[mm]
7.5
40
7.5
7.5 60 100 Frame anchor MA-D 7.5x60 2 247 060 601
2 247 070 601
70
100 Frame anchor MA-D 7.5x70
80
7.5 100 100 Frame anchor MA-D 7.5x80 2 247 080 601
100 Frame anchor MA-D 7.5x100
2 247 100 601
7.5
Window Production Aluminium 7.5 120 100 Frame anchor MA-D 7.5x120 2 247 120 601
100 Frame anchor MA-D 7.5x150
7.5
150
2 247 150 601
180
100 Frame anchor MA-D 7.5x180
2 247 180 601
7.5
T30
RC2 Application range Technical Data
l Window installation into thermal insulation Head diameter 8.5 mm
T30
Drive
Window Installation Coupling / False Edge Inspection document l Efficient spaced fixing of windows and Minimum installation depth 30 mm
Direct fastening in masonry and concrete,
l
without any plugs
No. 2614091-02 EPH Dresden
Concrete
doors
page
Cross reference
Bit TORX ....................................72 l Installation according to the RAL quality as- Sand-lime brick, Solid brick 40 mm
®
Vertically perforated brick,
sociation guidelines for windows and doors
Hammer drill SDS plus ...............73 lightweight concrete, pumice, 60 mm
®
l With additional adjustment function through aerated concrete
Window Installation Window Installation Masonry / Concrete Masonry / Concrete Properties Soft wood 60 mm
fine thread
Hard wood
40 mm
Burglary-resistant (RC2)
l
Reduced forming moulding and exact fit
l
drilling method
due to perfect thread geometry Building materials Pre-drilling Ø /
6 mm
l Fast installation, reliable anchoring Concrete ≥ C12/15, Hammer drilling
Solid lime sand brick, solid brick
Window Installation Timber Installation process Perforated lime sand brick, Rotary drilling
Case-hardened steel
l
6 mm
Hollow block, timber
Vertically perforated brick ≥ Plan
5 mm
Drill Ø 6.2 mm frame holes, in-plant or on
l
site, spacing acc. to RAL quality assess-
omitted
Aerated concrete ≥ PP4
ment T12 Rotary drilling
l Align frame thoroughly in masonry opening Edge distance
Window Installation Attachments l Fix with EJOT frame anchor by using com- With regards to edge distances, the
Drill Ø 6 mm holes into stone, drill hole
l
depth = installation depth + 10 mm
manufacturer's instructions must be observed.
mon tools
Without instructions a minimum of 50 mm edge
Push-on cap if necessary
distance should be observed when using frame
l
anchors.
Note
Please note the special assembly instructions
Special Screws when installing burglar-proof devices!
Accessories / Tools