Page 50 - igs-ejot-gesamt_en
P. 50

Window Installation Masonry / Concrete
                                   Frame anchor
   Window Production  Plastics     EJOT  frame anchor type MA-D




                                        ®


                                        Ø   Length   PU Order description                 Article number
   Window Production  Timber        Zinc plated, blue passivated 100 Frame anchor MA-D 7.5x40  2 247 040 601
                                       [mm]
                                              [mm]
                                       7.5
                                               40
                                       7.5
                                       7.5     60    100 Frame anchor MA-D 7.5x60         2 247 060 601
                                                                                          2 247 070 601
                                               70
                                                     100 Frame anchor MA-D 7.5x70
                                               80
                                       7.5    100    100 Frame anchor MA-D 7.5x80         2 247 080 601
                                                     100 Frame anchor MA-D 7.5x100
                                                                                          2 247 100 601
                                       7.5
   Window Production  Aluminium        7.5    120    100 Frame anchor MA-D 7.5x120        2 247 120 601
                                                     100 Frame anchor MA-D 7.5x150
                                       7.5
                                              150
                                                                                          2 247 150 601
                                              180
                                                     100 Frame anchor MA-D 7.5x180
                                                                                          2 247 180 601
                                       7.5
         T30
                      RC2          Application range                        Technical Data
                                   l    Window installation into thermal insulation  Head diameter       8.5 mm
                                                                                                           T30
                                                                            Drive
   Window Installation  Coupling / False Edge  Inspection document  l    Efficient spaced fixing of windows and   Minimum installation depth  30 mm
                                       Direct fastening in masonry and concrete,
                                   l
                                     without any plugs
        No. 2614091-02 EPH Dresden
                                                                            Concrete
                                     doors
                         page
        Cross reference
        Bit TORX  ....................................72  l    Installation according to the RAL quality as-  Sand-lime brick, Solid brick  40 mm
             ®
                                                                            Vertically perforated brick,
                                     sociation guidelines for windows and doors
        Hammer drill SDS plus  ...............73                            lightweight concrete, pumice,   60 mm
                    ®
                                   l   With additional adjustment function through    aerated concrete
   Window Installation Window Installation  Masonry / Concrete Masonry / Concrete  Properties  Soft wood  60 mm

                                     fine thread
                                                                            Hard wood
                                                                                                         40 mm
                                        Burglary-resistant (RC2)
                                   l
                                       Reduced forming moulding and exact fit
                                   l
                                                                                                 drilling method
                                     due to perfect thread geometry         Building materials   Pre-drilling Ø /
                                                                                                          6 mm
                                   l    Fast installation, reliable anchoring  Concrete ≥ C12/15,   Hammer drilling
                                                                            Solid lime sand brick, solid brick
   Window Installation  Timber     Installation process                     Perforated lime sand brick,   Rotary drilling
                                      Case-hardened steel
                                   l
                                                                                                           6 mm
                                                                            Hollow block, timber
                                                                            Vertically perforated brick ≥ Plan
                                                                                                          5  mm
                                       Drill Ø 6.2 mm frame holes, in-plant or on
                                   l
                                     site, spacing acc. to RAL quality assess-
                                                                                                         omitted
                                                                            Aerated concrete ≥ PP4
                                     ment                                   T12                      Rotary drilling
                                   l    Align frame thoroughly in masonry opening  Edge distance
   Window Installation  Attachments  l    Fix with EJOT frame anchor by using com-  With regards to edge distances, the
                                       Drill Ø 6 mm holes into stone, drill hole
                                   l
                                     depth = installation depth + 10 mm
                                                                            manufacturer's instructions must be observed.
                                     mon tools
                                                                            Without instructions a minimum of 50 mm edge
                                      Push-on cap if necessary
                                                                            distance should be observed when using frame
                                   l
                                                                            anchors.
                                   Note
                                   Please note the special assembly instructions
    Special Screws                 when installing burglar-proof devices!
    Accessories / Tools
        50
   45   46   47   48   49   50   51   52   53   54   55