The Fastener.





           Quality through research


           EJOSEAL





           Increased corrosion protection through high-quality sealant



           In order to stabilise the passivation layer of galvanised
           zinc or zinc alloy coatings, sealants are added as an
           additional layer.

           EJOSEAL is an inorganic, silicium-based sealant, to
           increase the corrosion and heat resistance of fastening
           elements with zinc or zinc alloy coatings. EJOSEAL is
           silicone-free and solvent-free, ecologically safe and it
           does not contain chromate in the dry film.      With EJOSEAL coating

           The applied layer is transparent. EJOSEAL does not
           contain wax and is ideally suitable for direct fastening
           into plastic.

           EJOSEAL offers the following advantages:

           l   Corrosion protection up to 240 h NSS until
              Fe corrosion more is also possible
           l   Ecologically safe                           Without EJOSEAL coating
           l   Free from silicone and solvents             Corrosion after 456 h testing according to DIN 50021 (coating thickness zinc 8μ blue)
           l   UV-resistant
           l   Good adhesion and minimal abrasion
           l   Heat resistant up to 150°C











           Verification procedure
           Fire protection





           According to ETA-10/0200 proof of fire resistance test for screws not required.



           With regards to fire protection the European Technical   The evaluation of fire resistance is only relevant for the
           Approval ETA-10/0200 assumes, that screws fulfill the   mounted system (screws, profile and substructure),
           class A1 requirements (non-combustible) with respect to   which is not subject to this European Technical Approval.
           fire behaviour, and in accordance with the commission
           decision 96/603 / EC (including changes) they do not   A direct proof of the fire resistance for EJOT frame
           have to be examined because of the listing in this deci-  anchors is not available.
           sion.